ProboStat Button Cell Test Fixture

The ProboStat™ is a system for measurements of electrical properties, transport parameters, and kinetics of materials, solid/gas interfaces and electrodes under controlled atmospheres at high temperatures up to 1600ºC. The versatile construction and broad range of accessories of the system are based on years of development and experience in the Kofstad/Norby group at the University of Oslo. A ProboStat™ system offers a cost-effective alternative to developing and building your own cell for studies, characterization and testing of inorganic materials, electroceramics, fuel cell components, membrane materials, etc.

The sample under test rests on a ca. 50 cm long support tube of alumina, inside a closed outer tube of alumina or silica. The sample can be contacted with 2, 3 or 4 electrodes of e.g. platinum, using disk, van der Pauw, or bar geometries. A spring-loaded alumina assembly holds the sample and electrodes in place. 16 electrical feedthroughs allow use of 4 shielded electrode leads, surface guard, and up to three thermocouples (e.g. for Seebeck coefficient measurements). Electrical connections are made via coax cables suitable for standard impedance spectrometer connectors, and standard thermocouple compensation cables. Gases can be fed in single or dual chamber modes directly onto or from electrodes, allowing measurements under controlled atmospheres, transport number measurements in gradients, and testing of fuel cell, pump, and sensor components. Gas supply is via Swagelok quick-connects.

ProboStat System indicating Key Access Points
ProboStat System indicating Key Access Points

Specifications

  • Outer tube diameter: 40 mm
  • Overall length: 75 cm, shorter versions available (-10, -20, -30 cm)
  • Single end cell assembly
  • Sample fixation: spring force via alumina rods
  • All hot-zone electrode leads detachable via feedthrough mini-connectors
  • Support tube systems from 10 to 24 mm diameter detachable
  • For up to 24 mm diameter disk samples
  • For up to 50 mm long bar samples
  • Temperature: typical long term: < 1400ºC, short term: < 1600ºC
  • Atmosphere: Oxidizing, reducing, or corrosive; wet or dry; from small overpressure to low vacuum
  • 6 BNC electrode connections for impedance spectrometers etc.
  • Internal shields bridging, ground and guard switches
  • 3 thermocouple connections
  • 4 Swagelok gas quick-connects to 1/8” tubing (other connections on request)
  • Standard materials: Alumina AL23, Pt, Pt10%Rh, Stainless Steel
  • Water cooling (or heating) of cold end base unit is possible
  • Spare parts supply, also of hot zone consumables