Specialists in Electrochemistry & Materials, Energy & Power

  NANOBASE

XperRam - S Raman System

Confocal Raman Spectroscopy Imaging

Description:

This is the most popular configuration in the range, offering the optimum mix of high performance, flexibility and affordability.

It utilises confocal/3D Raman imaging and analysis, fast 2D scanning over a wide area (200µm x 200µm). Includes bright field microscope imaging, up to three laser/filter combinations (532-1064nm), interchangeable and rotatable VPH grating, Photoluminescence and Electroluminescence.

The interchangeable VPH grating deliversensure that you gain high spectral efficiency in your measurement’s vs other technologies.

A complete laboratory instrument that will suit most application needs, the modular design alows for future expansion as your research develops and budgets allow.

Included as standard:

  • Reflected LED illuminator for bright field
  • Mechanical X-Y stage with right hand control
  • Automatically controlled Z-axis position
  • Include main frame, stage plate, control box, interface cable, power cable.r

 

Software:

All Spectrometers come with the Nanospectrum Software Suite

  • Raman/PL spectrum acquisition & imaging
  • Spectrum data export format: .txt, .csv
  • 2D mapping data export format: .spm, .csv
  • Option: TRPL spectrum acquisition & imaging
  • Option: Photocurrent acquisition & imaging

Nanobase’s patented interchangeable VPH grating delivers higher spectral efficiency in your measurement’s vs. other technologies.

This instrument is a complete laboratory instrument that will suit most application needs.

System Configurations:

The XperRam – S can come in two configurations either with the 2D Raman imaging and scanning module or without. These are the XperRam -S-2D and XperRam-S-N

You then have a choice and option to customise your Raman solution on the following options on Raman laser, optical filter, grating and spectrometer which can all be found in the system specifications tables below.

 

Optional Accessories

  • Computer System
  • Aluminium Optical Table
  • Acrylic Box Cove
 

 Specifications

 XperRAM-S-2D XperRAM-S-N
Microscope (Olympus BX43) for 2D Scanning or No Scanning - Reflected LED illuminator for bright field
- Mechanical 3-axis stage with right-hand control
- Consists of:
1. Main frame of microscope
2. Illuminator
3. Quintuple revolving nosepiece
4. Stage plate C2
5. Power cable
- Reflected LED illuminator for bright field
- Mechanical 3-axis stage with right-hand control
- Consists of:
1. Main frame of microscope
2. Illuminator
3. Quintuple revolving nosepiece
4. Stage plate C2
5. Power cable
Objective 40X
- Magnification: 40X
- Numerical aperture: 0.75
- Working distance: 0.63 mm
- >60% transmission from 360 nm to 1000 nm
40X
- Magnification: 40X
- Numerical aperture: 0.75
- Working distance: 0.63 mm
- >60% transmission from 360 nm to 1000 nm
Objective (Other options) 10X, 20X, 50X, 100X Long WD 40X (recommended for photocurrent) 10X, 20X, 50X, 100X Long WD 40X (recommended for photocurrent)
Laser Scanning Module for 2D or 3D Scanning functionality - Wavelength range: 400~1000 nm
- Laser scanning mode: Raster scan
- Scanning area: 200 umX200 um (when using a 40X objective lens)
- Includes a 3 MP camera for optical image acquisition (FOV: 220 um X150 um when using 40X)
C5 - A controller is included (USB1.1).
Point Measuring Module for No Scanning functionality - Wavelength range: 400~1000 nm
- Include a 3 MP camera for optical image acquisition (FOV: 200 um X150 um)
Raman Laser Options (At least 1 needed XperRF, XperRam S can choose up to three) - 532 nm Freespace
- 532 nm Freespace for low frequency measurement
- 405 nm Freespace
- 633 nm Freespace
- 785 nm Freespace
- 1064 nm Freespace
- 532 nm Freespace
- 532 nm Freespace for low frequency measurement
- 405 nm Freespace
- 633 nm Freespace
- 785 nm Freespace
- 1064 nm Freespace
Optical Raman Filter Options (Choose the ones matching your laser selctions) - 532 nm Raman PL filter
- 532 nm Raman filter for low frequency measurement
- 405 nm Raman PL filter
- 633 nm Raman PL filter
- 785 nm Raman PL filter
- 1064 nm Raman PL filter
- 532 nm Raman PL filter
- 532 nm Raman filter for low frequency measurement
- 405 nm Raman PL filter
- 633 nm Raman PL filter
- 785 nm Raman PL filter
- 1064 nm Raman PL filter
System Platform - 2 slots to adapt laser ND filters or polarizers
- 2 slots to adapt polarizers or waveplates
- 1 slot to adapt an interchangeable Raman-PL filter set
- Up to 3 DPSS lasers are installable.
- Provides robust platform for stable beam alignment
- 2 slots to adapt laser ND filters or polarizers
- 2 slots to adapt polarizers or waveplates
- 1 slot to adapt an interchangeable Raman-PL filter set
- Up to 3 DPSS lasers are installable.
- Provides robust platform for stable beam alignment
Spectrometer XPE 200 Monochromator
- Input aperture ratio: f/5
- Focal length: 200 mm
- A volume phase holographic grating is mountable (Also, interchangeable).
- Micrometer for adjustment of range of interest
- Spectral range: Max. 5940 cm-1
(Example: ~2010 cm-1 when using a 1800 lpmm VPH grating, 532 nm laser)
- Spectral resolution (FWHM): Min. 2.5 cm-1
(Example: 3.7 cm-1 when using a 1800 lpmm VPH grating, 532 nm laser)

Detector
- Back-illuminated CCD, Deep-Depletion with anti-fringing
'- Active pixels: 2000 '× 256 pixels
- Pixel size: 15 'x 15 um
- Dark current: As low as 0.033 e-/pixel/sec
- Quantum efficiency: >40% from 400 nm to 1000 nm
Extender for XPE200
- Variable slit
1. Slit width: 6 mm
2. Graduation: 10 um/division
3. Slit centering tolerance: '±0.08 mm
- Focal length: 200 mm
XPE 200 Monochromator
- Input aperture ratio: f/5
- Focal length: 200 mm
- A volume phase holographic grating is mountable (Also, interchangeable).
- Micrometer for adjustment of range of interest
- Spectral range: Max. 5940 cm-1
(Example: ~2010 cm-1 when using a 1800 lpmm VPH grating, 532 nm laser)
- Spectral resolution (FWHM): Min. 2.5 cm-1
(Example: 3.7 cm-1 when using a 1800 lpmm VPH grating, 532 nm laser)

Detector
- Back-illuminated CCD, Deep-Depletion with anti-fringing
'- Active pixels: 2000 '× 256 pixels
- Pixel size: 15 'x 15 um
- Dark current: As low as 0.033 e-/pixel/sec
- Quantum efficiency: >40% from 400 nm to 1000 nm
Extender for XPE200
- Variable slit
1. Slit width: 6 mm
2. Graduation: 10 um/division
3. Slit centering tolerance: '±0.08 mm
- Focal length: 200 mm
Grating Options - 300 lpmm at 900 nm
- 600 lpmm at 600 nm
- 1200 lpmm at 840 nm
- 1800 lpmm at 532 nm
- 2400 lpmm at 450 nm
- 300 lpmm at 900 nm
- 600 lpmm at 600 nm
- 1200 lpmm at 840 nm
- 1800 lpmm at 532 nm